Parallel Misalignment

Parallel Misalignment
If the machine speed can be varied, the vibration due to imbalance will vary as the square of the speed. If the speed is doubled, the imbalance component will rise by a factor of four, while misalignment-induced vibration will not change in level
Following is a typical vibration spectrum from a misaligned machine.

DLI Engineering provides products and services for Predictive Maintenance including vibration analysis instruments, monitoring and diagnostic software, and consulting for CBM programs.